WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Safety notes
Safety extra low voltage 24 V DC!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area
- Keep away People from the operating area of the
drive
- Keep away children from the control
- Use only in dry rooms
- Only for inside mounting.
Use rain detector with danger of rain
- Just use unchanged original D+H parts
Observe enclosed r ed safety slip!
! IMPORTANT ! Safety Notes
1. Mounting of the drive should be carried out by a D+H distributor, whose qualification and experience is
ensured by regular in-house training.
2. All wiring must be installed by a qualified electrican according to National Electrical Codes, NFPA 70.
3. For indoor use only. Use always rain detector with danger of rain (e.g. at domelights or roof windows).
4. Observe enclosed red safety slip!
5. Danger of violent pressure in handaccessible area.
6. The window operators have been evaluated for Residential or Light Duty Commercial Use only.
7. A suitable field wiring means should be provided in the end use application.
8. The mounting and routing of external wiring should be determined in the end product.
9. The mounting of each unit shall be evaluated in the end use.
10. The suitability of the leads for field wiring should be determined in the end-use application.
11. The drive must be mounted a min of 8 feet above the floor or any access level.
12. The drives were not evaluated for entrapment protection since they are to be installed at least 8 feet above
the floor. Where entrapment is a consideration, the need for additional tests and evaluation should be
determined during the end product investigation.
13. The drive shall be connected to a Class 2 power supply.
For North America:
14. The Uniform Building Code Standard Vols. 1, 2 & 3 have to be observed.
2/12
LDCO 1000/038 -L/-R
Intended use
- Drive for electric opening and closing for Co
louvre windows
- The louvre must be prepared by the louvre
manufacturer for the application of the drive
- Operating voltage 24 V DC
- Usable for smoke extraction as well as daily
ventilation
- Only for inside mounting
Performance Features
- Microprocessor controlled synchro electronics
for a precise synchronous run of up to 2 drives
(Tandem programming required by SCS software)
- Individually programmable (via software SCS)
- Protection system for the main closing edge
Extent of supply
Drive unit with 2,5 m silicone cable.