Operating Instructions
Operation (Continued)
Do not use
hoses or fi ttings
that are damaged or deteriorated.
Never carry a tool
by the hose or
pull the hose to move the tool or a
compressor. Keep hoses away from
heat, oil and sharp edges. Replace any
hose that is damaged, weak or worn.
LUBRICATION
Air tools require lubrication throughout
the life of the tool and is the owner's
responsibility. Failure to lubricate the air
tool properly will dramatically shorten the
life of the tool and will void the warranty.
This air tool
requires lubrication
BEFORE the initial use and BEFORE and
AFTER each additional use.
AUTOMATIC LUBRICATION
The recommended method for
lubrication is with an air line lubricator
installed as part of the air piping system.
See Figure 1. Use Campbell Hausfeld air
tool oil ST127000AV or equivalent ISO
grade 32 oil.
MANUAL LUBRICATION
If an air line lubricator is not used, the
tool must be lubricated daily.
Disconnect the
air tool from the air
supply before lubricating.
1. Disconnect the air tool from the air
supply.
2. Turn the air tool upside down.
3. While pulling the trigger, squeeze
approximately a 1/4 oz. of Campbell
Hausfeld airtool oil in the air inlet. If
applicable, switch the forward and
reverse valve in both directions.
4
lubricated, oil will discharge through
the exhaust port during the fi rst few
seconds of operation. The exhaust port
must be directed away from your body
before applying air pressure.
4. Connect the air tool to the air supply
and cover the exhaust port with a
towel (refer to replacement parts
manual for tool features). Run the
tool in both the forward and reverse
directions, if applicable, for 20 to 30
seconds. Oil will discharge from the
exhaust port when air pressure is
applied.
ATTACHMENTS
before changing attachments or serious
injury could occur.
1. Insert stem of grinder attachment into
collet opening (See Figure 2). Make
sure stem is fully inserted.
Figure 2
2. Securely tighten collet with
wrenches (supplied with some
models) (See Figures 3 & 4). Apply
one wrench to the collet nut and
the other to the spindle. Turn the
wrench on the collet nut to the right,
simultaneously turning the other
wrench in the opposite direction.
Make sure stem does not slip out of
position.
www.campbellhausfeld.com
After an air tool
has been
Disconnect air
tool from air supply
Grinder
Attachment
Collet Nut