Troubleshooting
If...
White or glittering
flakes floating in the
hot water.
Rough milky white
substancess are
adhered to inner
container.
Boiling sounds
become louder.
Hot water has odors
of chlorine.
Hot water has an
unpleasant odor.
Hot water comes out
by itself.
Hot water does not
flow out smoothly.
Electric dispense
Air dispense
The indicator lights
flash alternately.
Hot water does
not dispense.
Electric dispense
Air dispense
If the problem is not fixed after checking the above possible causes, or if you think something is strange, disconnect the body plug
from the unit. Wait at least 10 seconds and then re-connect the plug.
The semi-transparent inner part inside the lid may become yellowish. This does not affect operation of the unit.
The rattling noise in the lid is made by small ball-shaped components which prevent water from flooding out
if the unit topples over.
If the room temperature is very high, the outside of the main unit may reach about 120°F (50℃).
The unit does not
turn on.
The indicator lights
flash alternately
and H1 or H3 is
displayed.
22
06_USA_OM_NC-DG3000_EN.indd 22
06_USA_OM_NC-DG3000_EN.indd 22
Before calling a service supplier,
please check the following possible causes.
Possible cause
The cause of this is "scale". (see P.20)
It is not flakes of fluororesin.
* Water with a large content of minerals in it such
as mineral water or ionized water, is more likely to
cause a scale or white layer in the hot water.
When "scale" adheres, boiling sounds become louder.
Odors of chlorine remain depending on the amount of
chlorine in tap water.
When the unit is new, resin used in the manufacturing process may give off a mild odor. This will
disappear with use.
If the unit is placed on surfaces such as a vinyl sheet, the odor may be carried over into the water.
Water has been added above maximum water level.
The mesh filter may be clogged with "scale".
(See P.20)
When scale accumulates in the inner container and
remaining hot water is low, hot water does not flow
out smoothly.
Immediately after boiling, hot water may not flow out
smoothly.
Rubber gaskets may be damaged.
It is harder to dispense if the keep-warm temperature or water level is low.
Overheating protection has been activated (See P.15)
The indicator lights may flash alternately by adding
boiling water or the way the water is supplied.
When the inner container is cleaned with citric acid,
citric acid has built up on the bottom.
The automatic lock has been engaged.
The Push plate lock lever is locked.
The lid is opened.
You poured in water directly from a tap.
You put the unit on the sink.
You turn the unit upside down with its bottom wet.
You washed the unit in water.
This is malfunction of the sensor.
Contact the stores where you purchased.
How to fix
Clean the inner container with a wet
soft sponge. (See P.20)
If the "scale" still remains, clean with
citric acid. (See P.21)
Press
key to reduce the
chlorine. (See P.16)
Lower the water level.
Clean the filter with a brush.
If the "scale" cannot be removed,
replace the filter (See P.23)
Replace gaskets. (See P.23)
Add water and press
Press
key.
Disconnect the plug, and stir the citric
well to dispose.
Press
key.
Unlock the Push plate lock lever.
Close the lid securely.
It is broken if the electric components
are immersed in water.
Contact the store where you
purchased the unit for repair.