Single Pole (1 Location)
120VAC, 60Hz
Rotary Dimmer
Cat. No. 6602, 600W
INSTALLATION INSTRUCTIONS
Unipolaire (1 emplacement)
120 V c. a., 60 Hz
Gradateur rotative
Nº de cat. 6602, 600 W
DIRECTIVES D'INSTALLATION
Unipolar (1 ubicación)
120VCA, 60Hz
Atenuador Giratorio
No. de Cat. 6602, 600W
INSTRUCCIONES DE INSTALACION
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit
of anyone else that this product at the time of its sale by Leviton is free of
defects in materials and workmanship under normal and proper use for
two years from the purchase date. Leviton's only obligation is to correct
such defects by repair or replacement, at its option, if within such two
year period the product is returned prepaid, with proof of purchase date,
and a description of the problem to Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little
Neck, New York 11362-2591. This warranty excludes and there is
disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused, or altered
in any manner, or is not used under normal operating conditions or not
in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a
particular purpose, but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to two
years. Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform this warranty
obligation. The remedies provided herein are the exclusive remedies under
this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com
• RFI filter for radio/TV interference
• Fits standard wall boxes
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING:
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO
CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-OPERATED APPLIANCE.
OTHER CAUTIONS:
1. DISCONNECT POWER WHEN SERVICING FIXTURE.
2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR
CU/AL.
GANGING/DERATING:
When two units are ganged together, use no more than 500W load on each device. When three or more units are ganged together, use no more
than a 400W load on each unit.
TO INSTALL:
WARNING:
1.
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS
OFF BEFORE WIRING!
2. Remove existing wallplate and switch, if applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight.
4. Connect wires per WIRING DIAGRAM as follows: Twist strands of each lead tightly together and, with circuit conductors push firmly into
appropriate wire connector. Screw connectors on clockwise making sure no bares conductors show below the wire connectors. Secure each
connector with electrical tape.
5. Installation may now be completed by carefully positioning all wires to provide room in outlet box for dimmer. Mount dimmer into box with
mounting screws supplied. Attach wallplate and knob.
6. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
DI-000-06602-25B
• Avec filtre antibrouillage radioélectrique
• S'adapte à toute boîte simple standard
AVERTISSEMENT :
AVERTISSEMENT :
AVERTISSEMENT :
APPAREILS RACCORDÉS, NE PAS L'INSTALLER POUR COMMANDER UNE PRISE, UN LUMINAIRE FLUORESCENT, OU UN APPAREIL
MOTORISÉ OU À TRANSFORMATEUR.
AUTRES MISES EN GARDE :
1. LORS D'UNE VÉRIFICATION D'APPAREILS, COUPER L'ALIMENTATION.
2. UTILISER CE DISPOSITIF SEULEMENT AVEC DU FIL DE CUIVRÉ; POUR LE FIL EN ALUMINIUM, UTILISER SEULEMENT LES
DISPOSITIFS PORTANT LA MARQUÉ CO/ALR OU CU/AL.
GROUPEMENT/ABAISSEMENT : si deux unités sont combinées, la charge de chacune des unités ne doit pas dépasser 500 W.; si trois unités
ou plus sont combinées, chaque charge ne doit pas dépasser 400 W.
INSTALLATION :
AVERTISSEMENT :
1.
LE COURANT AU FUSIBLE OU AU DISJONCTEUR ET S'ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À
L'INSTALLATION.
2. Retirer la plaque murale et l'interrupteur existant, le cas échéant.
3. Dénuder l'extrémité de chaque fil du circuit afin d'exposer 1,9 cm (0,75 po) de cuivre; s'assurer que les brins soient bien droits.
4. Raccorder les fils conformément au SCHÉMA DE CÂBLAGE et de la façon suivante : entortiller fermement les brins de chaque fil et les
enfoncer, avec le conducteur de circuit approprié, dans des serre-fils de format convenable; tourner ces derniers vers la droite en s'assurant
qu'aucun brin ne dépasse; protéger les raccords au moyen de ruban isolant.
5. Enfoncer délicatement les fils dans la boîte murale en prévoyant suffisamment d'espace pour le gradateur; installer ce dernier au moyen des
vis d'assemblage fournies; fixer la plaque murale et le bouton.
6. Rétablir le courant au fusible ou au disjoncteur; L'INSTALLATION EST TERMINÉE.
DI-000-06602-25B
English
FEATURES
INSTALLATION INSTRUCTIONS
Français
CARACTÉRISTIQUES
DIRECTIVES D'INSTALLATION
INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN QUALIFIÉ.
POUR ÉVITER LA SURCHAUFFE OU L'ENDOMMAGEMENT ÉVENTUEL DE CE DISPOSITIF ET D'AUTRES
POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE MORTELLE, COUPER

Publicité

loading

Sommaire des Matières pour Leviton Trimatron 6602

  • Page 1 Leviton warrants to the original consumer purchaser and not for the benefit • Avec filtre antibrouillage radioélectrique of anyone else that this product at the time of its sale by Leviton is free of • S’adapte à toute boîte simple standard defects in materials and workmanship under normal and proper use for two years from the purchase date.
  • Page 2 CARACTERISTICAS de sa vente par Leviton, et n’en présentera pas tant qu’il est utilisé de façon normale et adéquate, pendant une période de 2 ans suivant la date d’achat. La seule •...