9.
TROUBLE SHOOTING
9.1
Error code displayed
Fault
Ambient air temperature
is too high or too low
Water temperature
sensor error
Ambient temperature
sensor error
Low pressure protection
9.2
Other malfunctions
Fault
The heat pump does not
start up
The heat pump stops in
an untimely manner
10.
MAINTENANCE AND WINTERIZING
During winter, or when the ambient air temperature falls below 0°C, drain water from the heat pump to
avoid damage to the titanium heat exchanger caused by freezing of water in the machine. This would entail
cancellation of the guarantee.
From time to time, check that machine gratings are not obstructed with dirt (dust, grass cuttings, pollen
and dead leaves, petals, etc.).
For maintenance interventions or scrapping, contact an approved maintenance centre.
Code
P0
P1
P2
EL
Observation
Nothing displayed on
the control panel
The water temperature
is displayed on screen
No error code
The water temperature
is displayed on screen
No error coder
Cause
The ambient
temperature is outside
the operating range, 11
- 42°C
Controller fault
Water temperature
sensor defective or
short circuit
Ambient temperature
sensor defective or
short circuit t
Low pressure switch
disconnected or
defective.
Gas leak
Cause
The heat pump is not
energised
The water temperature
is above or equal to the
set point
The heat pump just
started
Air circulation is
insufficient
Lack of R32
The fan is defective
Solution
Wait until the
temperature falls below
40°C or rises above
13°C before restarting.
Replace the controller
Replace the water
temperature sensor
Replace the ambient
temperature sensor
Have the device
repaired by a
professional.
Solution
Check the condition of
the cable, the differential
switch and the circuit
breakers
Check the set point
selected
Wait for the time-out to
finish (3 minutes)
Check that air can
circulate freely through
the machine.
Call your supplier for
after sales service.