Télécharger Imprimer la page

Whirlpool WOEC5030L Guide De Dimensions page 2

Publicité

Les langues disponibles

Les langues disponibles

DIMENSION GUIDE
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
■ Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
■ Grounded electrical supply is required. See "Electrical
Requirements" section.
■ Electrical supply junction box should be located
3" (7.6 cm) maximum below the support surface when the
oven is installed in a wall cabinet. A 1" (2.5 cm) minimum
diameter hole should have been drilled in the right rear or left
rear corner of the support surface to pass the appliance cable
through to the junction box.
■ Oven support surface must be solid, level and flush with
bottom of cabinet cutout. Floor must be able to support a
total weight (microwave and built-in oven) of 249 lbs (113 kg)
for 30" (76.2 cm) models.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Cabinet Dimensions - Built-in Microwave/Oven
Combination
Standard Installation
F
E
30" (76.2 cm) models
A. 30" (76.2 cm) minimum cabinet width
B. 1
" (3.2 cm) top of cutout to bottom of upper cabinet door
1
4
C. 19
" (48.9 cm) bottom of cutout to floor is recommended.
1
4
7.5"-19
" (19.1 cm-48.9 cm) bottom of cutout to floor is acceptable.
1
4
D. 28
" (72.4 cm) minimum cutout width
1
2
E. 1
" (3.8 cm) minimum bottom of cutout to top of cabinet door
1
2
F. 41
" (105 cm)* recommended cutout height
5
16
G. 24" (60.7 cm) cutout depth
*NOTES: The cutout height can be between 41
(104.5 cm and 105.6 cm) for microwave/oven combination.
B
D
G
C
/
" and 41
1
8
Flush Installation
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 1/4" (6 mm) reveal on the top, a
1/4" (6 mm) reveal on the sides, and a 1/8" (3 mm) reveal on the
bottom of the wall oven.
The front face of the cleats and platform will be visible and should
be treated as a finished surface.
F
30" (76.2 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 30
" (76.8 cm) minimum width of flush inset cutout
1
4
C. 28
" (73.3 cm) minimum width of opening
7
8
D. 44
" (112.5 cm) minimum height of flush inset cutout
5
16
E. 42
" (107.9 cm) recommended cutout height
1
4
F. 11/16" (1.7 cm) side cleat*
G. 1/2" (1.3 cm) spacer the entire depth of the cutout*
H. Recommended junction box location
I. 4
"-19
" (11.7-48.9 cm) bottom of cutout to floor
5
1
8
4
J. 25" (63.5 cm) minimum depth of cutout
*Cleats and spacers must be recessed 1
front of the cabinet.
30" (76.2 cm) models
/
"
1
A. 2" (5.1 cm) spacer the entire depth of the cutout*
2
B. 25" (63.5 cm) depth of cutout
C. 1
" (3.5 cm) recess from front of cabinet
1
2
D. 11/16" (1.7 cm) side cleat*
*Cleats and spacers must be recessed 1
front of the cabinet.
FRONT VIEW
SIDE VIEW
A
B
C
D
E
F
G
G
J
H
H
I
A
A
C
D
D
/
" (3.5 cm) from the
3
8
TOP VIEW
/
" (3.5 cm) from the
3
8
2 of 9
B

Publicité

loading