3. Installation
Before mounting and removing the sensor, make sure that no
pressure is applied to the system.
1. Screw the sensor into a G¾
process fitting.
2. Tighten the sensor with a
spanner until you can feel the
end stop.
The housing (A) is freely rotat-
able.
You can replace the Viton O-ring
(B) by the supplied EPDM O-ring.
The unit is adaptable for various
G¾
process
adapters to be ordered separate-
ly as accessories).
• Welding adapter:
Weld the adapter first. Then
mount the sensor.
• Prozess adapter:
Mount adapter (D) to the sen-
sor first, then sensor + adapter
to the process connection by
means of a nut, a clamping
flange or similar.
If it is not possible to slide the fixing element (C) down over the top of
the sensor: slide it up over the bottom of the sensor before the adap-
ter is mounted.
20
fittings
(G¾
A
36
B
C
D