VERTICAL ANGLE SET
·
Press the power button and "R/L " simultaneously. "F1" will be displayed.
·
Press the „O-SET" button. Indication: „F1" - first rotation (A).
·
Confirm the adjustment via collimator with „O-SET" .
·
Rotate.
·
„F2" will be displayed - second rotation (B).
·
Confirm the adjustment via collimator with „O-SET" .
HORIZONTAL ANGLE CLOCKWISE / ANTI-CLOCKWISE HA
Aim at target "A" using the crosshair of the telescope. Press the "R/L " key; change the horizontal angle
mode HA
into the mode HA
R
angle. Press the "R/L " key once again to change the mode HA
HORIZONTAL ANGLE HOLD
Turn the tangent screw and set the required horizontal angle. Press the "HOLD" key once, and the
value of the horizontal angle flashes. Press the "HOLD" key once again to hold the horizontal angle.
Aim at the target. Press the "HOLD" key again to release at the required horizontal angle. The "HOLD"
key has no effect to the vertical angle.
SLOPE PERCENT MODE (%)
Press the button "V%" to switch from the vertical angular measurement shown in degrees into percent
indication. Press the button "V%" again to turn back to normal angle measurement mode.
ANGULAR REPEATED MEASUREMENT
1
Press the "SFT" key
2
Press the "REP" key
3
Aim at a target "A" and press the "0SET" key
4
Aim at target "B"
5
Press the "HOLD" key
6
Aim at target "A" once again and press the "0SET" key
7
Aim at target "B" once again
8
Press the "HOLD" key
9
Repeat steps 2 - 8 to measure the desired number of repetitions
10
Press the "SFT" key to exit this mode