34
34
A-Series
Routing and connecting the electrical supply
1
Fit the fuse holder along with fuse in close proximity to the vehicle battery.
2
Connect the long red cable with the angled end lug to solenoid in the pump mod-
ule. Route the cable towards the battery through the drilled hole in the vehicle floor
and connect it to the fuse holder and make connection secure. The length of the
long red cable can be shortened if too long. In this case, use the supplied cable lug
that fits on the fuse holder.
Connect the short red cable. Mount one end to the fuse and the other end up to
the 12V positive terminal on the vehicle battery.
3
Connect the black ground cable. Fasten one end to the pump module and the other
end to a suitable grounding point. A suitable grounding point is an area of clean met-
al on the vehicle chassis, free from dirt and paint.
4
Connect the hand-held control to the corresponding socket on the pump module.
Fasten the cable with the p clip to minimise strain on the connection. Fit the holder
for the hand-held control in close proximity to the lift so that it is easily accessible
when needed.
See supplementary illustration on next page.
Pump module
Note!
45° angle cable lug
Ground
Black
Fuse 100 Amp
Long red
Short red
+12V