Oven mode
Defrost
Dough proving
Temperature
sensor
CORE TEMPERATURES
Dish
Beef
Steak
Tenderloin
Pork
Roulade
Veal
Roast
Veal shin
Poultry
Chicken
Duck filet
Lamb
Leg of lamb, roast
Game
Saddle of hare /
venison
Leg of hare / hare
Fish
Salmon
Trout
Tuna
8
Troubleshooting
GENERAL TROUBLESHOOTING PROCEDURE
1. Try to find a solution for the problem with the help of the troubleshooting table.
2. If you cannot find a solution for the problem, contact the Inventum-servicedienst
TROUBLESHOOTING TABLE
Problem
The appliance does not start.
42
•
English
Description
Used for slowly defrosting food.
Used for proving yeast dough and sourdough.
Used for baking meat. The temperature sensor measures the
core temperature of the dish.
Core temperature
(°C) - rare
50
48
-
75
85
80
60
65
50
70
50
50
45
Possible cause
There is no power supply.
The mains cable is not connected.
Core temperature
Core temperature
(°C) - medium
(°C) - well done
55
65
52
56
63
70
80
85
88
90
83
86
65
70
70
75
55
65
75
80
55
65
55
65
50
55
Possible solution
Do a check on the fuse, if necessary
replace the fuse.
Make sure that the mains cable is
correctly connected to the mains
socket.
Temperature
range
-
30-45°C
40-99°C