Télécharger Imprimer la page

Forza SE Serie Manuel D'installation page 19

Masquer les pouces Voir aussi pour SE Serie:

Publicité

Les langues disponibles

Les langues disponibles

Gas Requirements
QUALIFIED SERVICE MAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS
SUPPLY CONNECTION.
High Altitude
For altitudes above 2,000 feet (610 m) above sea level, adjustments can be made with the instructions in the manual. If flame
performance is satisfactory, will not be required regulation. It is required that a Certified Professional make the high altitude
adjustments during installation.
Gas line must not come in contact with any components inside back cover of
the range.
If the line pressure supplying the appliance pressure regulator exceeds 14
inches W.C. (any gas), an external regulator must be installed in the gas line
ahead of the appliance regulator to reduce the pressure to no more than 14
inches W.C. Failure to do this can result in malfunction and damage to the
appliance.
The appliance must be isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas
supply piping system at test pressures exceeds, equal to or less than ½ psig
(3.5kPa.) and damage to the appliance.
19
EN

Publicité

loading

Produits Connexes pour Forza SE Serie

Ce manuel est également adapté pour:

Fr366seFr304se