VENTILATION (FAN)
If the fan increase or reduction buttons (VENT + or VENT –) are pressed when the system is switched off, only the evaporator
fan is activated, with the choice of 6 different speeds, shown on the central control unit display.
To switch off the fan it is necessary to set the value 0 on the central control unit display, using the fan speed reduction
button (VENT –).
SAVE BATTERY FUNCTION (AC/FAN)
The save-battery function starts when the power falls below a value of 10,4V.
In this case, the system (AC or VENT) shuts down, also deactivating the fan function and the message E1 appears on the
display and the battery symbol lights up.
When the power returns, for at least 10 seconds, to the value of 11,6V, the system is automatically reactivated, starting up
the condenser fan, followed by the evaporator fan and compressor.
ERRORS SHOWN ON THE DISPLAY (AC/FAN)
DESCRIPTION
Battery voltage
(The battery-saver device has cut in. Voltage has fallen below the value of 10,4V)
Fan over current cut-out
(The condenser or evaporator fan overloads the central control unit above the
limited allowed. Possible cause: short circuit or blockage of fan rotation.)
Compressor locked
(The rotor is locked or the pressure inside the cooling circuit is too high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the compressor cannot maintain the minimum rotation speed.)
High temperature on the central control unit
(If the cooling circuit is overloaded or the ambient temperature is
high, the central control unit signals this situation.)
Communication error
(There is no communication between the display and the central control unit.)
Temperature probe
(If the probe short-circuits or is not connected, the system stops.)
Tilt
The system shut-down device installed to operate in the event of tilting has cut in.
TEMPERATURE UNIT
When the system is switched off, it is possible to change the temperature unit, choosing between °C (Celsius) or °F
(Fahrenheit).
Press VENT + , VENT – , TEMP + and TEMP – , buttons simultaneously to show the preset unit (°C) on the display, and the
temperature symbol will light up (see fig.6).
Quickly press VENT + or VENT – to select the unit required.
REMOTE CONTROL
The remote control regulates both the conditioning function and the fan function.
Using the remote control it is possible to:
- Switch the system on and off
- Regulate the temperature
- Regulate the fan speed
- Engage the TURBO function
- Modify the TIMER function
ONLY FOR SALES WITHIN THE EUROPEAN COMMUNITY (EU)
This remote control is marked according to the European Directive 2012/19 / EU (WEEE) and the ordinance
RAEE 49/2014. The symbol on the product indicates that this product should not be treated as household
waste. Ensure that this product is not entered as part of the flows of municipal waste but treated as WEEE.
MESSAGE
11
SYMBOL
E1
E2
E3
E4
E5
E6
E7
E8