Télécharger Imprimer la page

Indel B SW OBLO 12V Manuel D'utilisation Et Entretien page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
SW OBLÒ 12V
OPERATION/CONTROL PANEL
"SLEEPING WELL OBLÒ" CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY
CONDITIONING (AC)
T
:
TEMPERATURE SET BY USER
0
T
:
AMBIENT TEMPERATURE DETECTED BY PROBE
amb
V
:
COMPRESSOR ROTATION SPEED (2500 Rpm)
1
V
:
COMPRESSOR ROTATION SPEED (4000 Rpm)
2
ON/OFF
When the system is switched off, pressing the ON/OFF button (see fig.1) for more than 2 seconds switches on the AC system in STANDARD
mode (V
) for a maximum of 6 consecutive hours and the half snowflake symbol lights up.
1
If the system is switched on, pressing this button for more than 2 seconds switches off the AC system.
About 30" after switching on, the ventilation starts up automatically.
The display always shows the temperature set by the user (T
The temperature which can be set by the user is between 17°C and 28°C.
TURBO
When the system is switched on, (by default in STANDARD mode - V
obtained by running the compressor at rotation speed V
Once this function has been activated, press the TURBO button again to return to speed V
TIMER
In STANDARD mode, the operating hours envisaged by the timer are 6.
In TURBO mode, the operating hours envisaged by the timer are 4.
If the system is switched on, every quick press of TIMER button (see fig.1) reduces the system operating time by 1 hour.
In TURBO mode, this button can be pressed to reduce the compressor operating time at speed V
Set the TIMER according to the power available.
TIMER adjustment
When the system is switched off, it is possible to vary the operating time envisaged by the timer in STANDARD mode between a minimum
of 1 and a maximum of 99 hours.
Press the VENT + and TEMP – buttons at the same, the display shows the default value (6 h) and the clock and half snowflake symbols
will light up (see fig.3).
Quickly pressing the VENT + or VENT – button increases or reduces the value by 1 hour each time the button is pressed.
Pressing the same buttons for longer increases or reduces the value in steps of 10 hours.
Also with the system switched off it is possible to change the operating hours envisaged by the timer in TURBO mode in the same way.
Press the VENT – and TEMP + buttons at the same, the display to show the default value (4 h) and the clock and full snowflake symbols
will light up (see fig.4).
Quickly pressing the VENT + or VENT – button increases or reduces the value by 1 hour each time the button is pressed.
Pressing the same buttons for longer increases or reduces the value in steps of 10 hours.
PROGRAMMED START FUNCTION
When the system is switched off, it is possible to set the programmed start of the system between 1 and 99 hours.
Quickly press the TURBO button, changes the value by 1 hour at a time and the clock symbol will light up (see fig.5).
Pressing the same button for more than 2 seconds changes the value in steps of 10 hours and the clock symbol will light up, remaining
lit until the system starts.
If you wish to deactivate the function, press the TURBO button until a value of 0 is reached, or switch on the system.
SW_OBLÒ_12V_20200219
).
0
) pressing TURBO (see fig.1), the maximum yield of the system is
1
for 4 consecutive hours and the full snowflake symbol lights up.
2
10
.
1
from 4 to 1 in steps of 1 hour.
2

Publicité

loading