Télécharger Imprimer la page

camry Premium CR 7929 Mode D'emploi page 6

Publicité

C. Temperature / timer down button
D. Temperature / timer up button
E. Sleep mode button
F. Fan speed selection button
G. Timer button
H. Air oscillation button
CONTROL PANEL manual operation – picture D
When the is powered on for the first time, the buzzer will shout, and then the device will get into standby status.
Press button "A" to turn on and turn off the device, the buzzer will play signal once.
MODE SELECTION on manual operation of control panel –
When the device is power on, choose mode you need between cooling mode or fan mode or dehumidifying mode as below:
Cooling mode -
- Press button "J" to select cooling mode, next press the button "L" to get slow fan speed button or press the button "M" to get fast fan
speed button. Next press button " C" or " D" to adjust required temperature from 16℃ to 31℃, buttons are not available in fan or
dehumidifying mode.
Fan mode -
- Press button "F" to select fan mode, the LCD screen will show "FA", next press the button "L" to get slow fan speed button or press the
button "M" to get fast fan speed button. During fan mode operation the temperature and sleeping functions cannot be setup.
Dehumidifying mode –
- Press button "K" to select dehumidifying mode, the LCD screen will show "dh". Under dehumidifying mode, sleep mode cannot be setup,
and fan speed is fixed on slow fan speed automatically and cannot be changed. In order to switch off the dehumidifying mode select other
operation mode: cooling or fan mode.
The function of drain plug ( ) is to drain the condensate water from the device's upper part. Its use
13
is determined according to the local air humidity. It is need to open the drain plug ( ) and pour out the condensate water if the device
13
operates when local air humidity is high or the device operates on dehumidification mode continuously for 12-24 hours continuously. In dry
cooling mode (low air humidity) it is not necessary to open the drain plug ( ) because there is no need to drain the condensate.
13
Timer set up -
- When the device is not working, press button "G", the LCD screen flashes, press the button "C" or "D" to set up the quantity of hours after
the device will start to operate. The LCD screen stops flashing and timer icon will be illuminated.
- When the device is working, press button "G", the LCD screen flashes, press the button "C" or "D" to set up the quantity of hours need to
pass before the device will shut off automatically. The LCD screen stops flashing, the timer icon will be illuminated, LCD screen shows
required to achieve temperature. This is a delayed start function.
Timer operation range can be fixed by each one hour from 1 to 24 hours.
Sleep mode –
- At first Press button "J" to cooling mode, next press button "E" to turn on the sleep mode, then the device will work on Energy-Saving and
quiet type.
- Next press button " C" or " D" to adjust required temperature from 16℃ to 31℃.
- The sleep mode is automatically programmed. After the first hour of operation, the temperature will increase by 1 ℃, after the second hour
of operation, the temperature will increase by another 1 ℃, and then remain at the same level.
- Press button "E" again to cancel sleep mode.
NOTE: Sleep mode is not available in dehumidify and fan modes.
Water full -
The water full indicator lamp "N" will be illuminated and the buzzer will alarm for several second, then the compressor will stop to work when
the inner device water tank will be full.
Automatic air oscillation function –
Press an air oscillation button (H), after the device turns on, automatic air oscillation function turns on, the louver will swing continuously
the left and the right; by pressing the button again the movement will stop and the louver remain in that position.
The radius of horizontal air oscillation is 30 degrees left and 30 degrees right direction from the middle vertical.
REMOTE CONTROLLER operation – picture E
The remote controller transmits signals to the system.
Button "A" - the device will be started when it is energized or will be stopped, if you press this button again.
Button "B" - press it to select operation mode: cool mode → dry mode → fan mode.
Button "C" / "D" - press to set up the operation time from 1 to 24 hours or required room temperature from 15 to 31°C when cooling mode is
6

Publicité

loading