The Network camera is equipped via an I/O terminal block with a digital input and a relay for device control.
At Pin 3 and Pin 4, an external digital input signal can be processed, whereby the voltage state is monitored
in the start phase at LOW. The output (Pin 1and Pin 2) can be used for switching external devices on and
off.
1 RELAY
2 RELAY
3 DI+
4 DI-
All manuals and user guides at all-guides.com
OUTPUT (output status open)
OUTPUT (max. 1A, 24V DC)
INPUT (max. 50mA, 12V DC
INPUT (output status of DI is low)