finishing
EN
9.9
clearances around appliance
Flush installation without
mantel
Enclosure
Appliance
opening
Appliance
Flush installation with mantel
12"
Enclosure
Enclosure
max.
Appliance opening
Appliance
note:
•
These are recommended minimum clearances only and are in supplied in good faith and not a guarantee
of compliance with TV manufacturers' maximum allowable operating temperatures. Always comply to TV
manufacturers' requirements.
TV temperatures must be validated at the time of installation as air flow characteristics within the
•
room can vary and maximum acceptable operating temperatures can vary from appliance to appliance.
TVs cannot be used where the TV temperature exceeds the manufacturer's maximum allowable operating
temperatures (see TV manufacturer's specifications).
•
Mantel height and depth must conform to mantel clearance requirements specified in this manual, see
"minimum clearance to combustible mantel" section in installation manual.
•
Dimension "A" the gap between the top of the finishing flange and the bottom of the TV are taken from the
top of the appliance opening.
•
TV temperatures may be further reduced by increasing the horizontal distance between the front of the TV
and the front edge of the mantel or by increasing dimension "A". However, increasing the gap between the
top of the mantel and the bottom of the TV beyond the maximum recommended figure, typically results in
higher temperatures. Minimum clearance between the mantel and bottom of the TV should be maintained to
allow air circulation below and behind the TV.
42
W415-2949 / D / 05.19.22
Flush installation with
mantel
TV bracket
Enclosure
Enclosure
Appliance
!
6" min.
These applications are
TV bracket
only acceptable when
the Universal Heat
2.5" min.*
Management kit is
installed.
2" min.
(3" max.
recommended)
0"
Recessed installation with
protrusion
6" min.
TV bracket
2.5" min.*
2" min.
(3" max.
recommended)
A
Enclosure
Appliance opening
See "minimum clearance to
A
mantle" section (installation
manual).
Partially recessed installation with mantel
WARNING
Enclosure
Appliance
6" min.
The volume of
TV bracket
air must be
added to the
enclosure to
accomodate
2.5" min.*
the recessed
area.
2" min.
(3" max. recommended)
Appliance opening
Appliance
6" min.
TV bracket
2.5" min.*
2" min.
(3" max.
12"
recommended)
max.
0"