Battery installation:
Alarm Unit
1. The battery compartment is accessed from the rear of the alarm unit by removing the back cover.
2. Insert 2 x "AA" size batteries (not included) conform the polarity as shown in the battery
compartment.
3. When the last battery is inserted the alarm will beep very loudly to indicate that the batteries are
installed properly.
4. Re-place the back cover again.
Remote Keyfob
The remote keyfob uses 1x A27 battery (included).
Note: The Battery Low indicator will light when the batteries needs to be replaced. Do not mix different
types of battery such as Alkaline and Carbon-zinc or old batteries with new. Remove the batteries if
the alarm will not be used for a period of time.
Alarm installation:
1. Place the alarm in the desired location with the rotary wall mount bracket.
Note: The motion detector of the alarm has a 6 meter range with approximate angles of 30º vertical
and 60º horizontal.
2. Fix the bracket to the wall with the supplied screws.
Note: The alarm can also be used without the bracket, as a free standing alarm.
Operation:
1. Press, at a distance of 10 meter, the "On" button of the remote control. A confirmation tone will
indicate that the alarm is armed and you have 30 seconds to leave the projected area. After this
time, if motion is detected, the alarm will sound.
2. Press, when entering the protected area, the "Off" button of the remote control within a distance of
10 meter to disarm the alarm. When entering the area, there is a short beep to indicate that motion
has been detected and you have a 4 second delay before the alarm will sound.
Learning remote keyfob code to the alarm unit:
After batteries installed, learn the Remote Keyfob code, press the Learn button on the Alarm unit and
press the 'On' button of keyfob. The Alarm unit will beep 2 times when set. The Alarm is ready to use.
Note: The alarm unit will need to relearn the Remote keyfob code every time the batteries are
replaced in either the alarm unit or the remote keyfob. One alarm unit can learn 3 remotes maximum.
Specifications:
Alarm:
130 dB
Detection:
Infrared
Exit delay:
30 seconds
Entry delay:
4 seconds
Battery:
2 x "AA" (not included)