Télécharger Imprimer la page

SUHNER ABRASIVE UTG 8-R Dossier Technique page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
ent work results.
Too great a pressure reduces machine efficiency and the
grinding belt's useful life.
The machine is equipped with an electronic control and
integrated overload protection.
If the machine is overloaded the belt blocks briefly. Im-
mediately remove all loads on the machine and keep it
running in the unloaded state for a short time.
Use a feed regulator to set and secure the pipe diameter.
Select a suitable belt speed.
Make sure when working that the machine is held at an
angle to the pipe so that the belt cannot slip off. The cen-
tre position can be checked at the yoke roller.
The handle lets you feel when the belt is pressed properly
against and around the pipe.
When the contact pressure is too low the belt may
slip on the drive roller!
4. S
ERvICE
4.1 p
reVentiVe mAintenAnce
To work effectively and surely keep the
machine and the ventilation slots clean at
all times.
After approx. 150 operating hours check carbon brushes
and replace if necessary. Clean motor housing and re-
plenish grease filling in gearbox housing.
To maintain the protective insulation the machine must be
subjected to a technical safety inspection. This work must
be done exclusively by a specialized electrical workshop.
When working on metal under extreme working conditions
conductive dust deposits can occur inside the machine,
thereby impairing the protective insulation of the tool. In
such cases the use of a stationary vacuuming system,
frequent blowing out of the ventilation slots and protection
by a fault current protection switch are advised.
4.1.1 c
hAnging the cArBon Brushes
The machine is equipped with two carbon brushes. The
carbon brushes must be changed as follows:
Loosen the screw and remove the cover.
24
/ m
aINTENaNCE
Raise the spring, and remove the carbon brushes. Clean
the carbon brush holders. Insert new carbon brushes. It
is imperative that the brushes are arranged in the correct
order. Replace the cover and tighten the screws.
4.2 s
pAre pArts
See page 2-5.
4.3 r
epAir
If the machine strict observance of the manufacturing and
testing method the tool should happen to fail, it must be
repaired by an authorized SUHNER agency.
Any replacement needed for the connecting line must be
installed by the manufacturer or its agent if safety risks are
to be eliminated.
4.4 w
ArrAnty
In the event of the tool being improperly handled, used
for purposes for which it is not intended and/or of the ser-
vice and maintenance instructions not being observed by
non-authorized persons, no warranty shall be in effect for
damages/consequential damages.
Complaints can only be honored if the machine is re-
turned in the undisassembled condition.
4.5 s
torAge
Temperature range during operation: -15°C to +50°C
Max. relative air humidity: 90% at +30°C, 65% at +50°C
4.6 d
/ e
isposAl
nVironmentAl compAtiBility
This machine consists of materials which can be dis-
posed of in a recycling process.
Before disposal, render the machine unusable.
Do not throw the machine into the garbage collec-
tion.
According to national regulations this machine
must be recycled in an environmentally-friendly manner.

Publicité

loading