Settings (con't)
Settings
80
80
Resume Schedule
75
75
Basic
Time
Humidity
Home
Away
Vacation
Away
Fan
65
72
BACK
Dehumidification
80
Enable Dehumidification?
Yes
75
Dehumidify Set Point
52 %
Over-Cooling Amount
0 ºF
Dehumidify Drain Timer
5 min.
Home
72
BACK
HUMIDIFICATION
Humidification
80
80
Enable Humidification?
No
Resume Schedule
75
75
Humidify Set Point
30 %
Humidify During...
Heat
Smart Control
Off
Away
Home
Humidity With Fan
Off
72
65
BACK
> Return to Table of Contents
Humidity Settings (Menu > Settings > Humidity)
Control your home's humidity settings for more ideal comfort.
44%
44%
Installer
Dehumidification (Menu > Settings > Humidity)
Enable Dehumidification – The system will attempt to reduce humidity in
cooling mode by reducing fan speed and over-cooling the space (when allowed
44%
by the Over-Cooling setting). The system will only reduce airflow if the room
temperature is within one degree of set point, otherwise, full cooling airflow will
be performed.
Dehumidify Set Point – The indoor relative humidity to be controlled to while
in cooling mode.
Over-Cooling Amount – The system will activate cooling, and possibly over-
cool the space by the desired number of degrees to improve dehumidification
performance in an effort to reach the dehumidify set point. The factory setting for
over-cooling is zero (no over-cooling) and can be adjusted up to 5 degrees of
over-cooling.
Dehumidify Drain Timer – At the end of a cooling cycle, if set, the
continuous fan setting will be turned off for the selected amount of time in order to
drain water from the indoor coil.
Humidification (Menu > Settings > Humidity > Humidification)
Enable Humidification – The system can control a humidifier attached to the
furnace or air handler to increase humidity in the space. It is important to note you
44%
44%
cannot humidify above the dehumidification set point.
Humidification Set Point – This setting allows you to choose the indoor
relative humidity desired, under which humidification will activate. The default is
humidification set point is 30% and is configurable between 15 and 45%.
Humidify During – Select the modes in which humidification will be
performed. Humidification can occur during heating, continuous fan and/or
cooling mode.
• Heat – Humidifier will operate with equipment during Heat if a
humidification demand is present.
• Heat/Fan – Humidifier will operate with equipment during these modes if a
humidification demand is present.
• Heat/Fan/Cool – Humidifier will operate with equipment during these
modes if a humidification demand is present.
EcoNet
Smart Thermostat User Guide
®
14