¡ We recommend piping with an exhaust air pipe dia-
meter of 150 mm.
¡ If the diameter of the air extraction ducting is less
than 150 mm, you need a separately available re-
duction fitting.
Note: If you are using an aluminium pipe, smooth the
connection area beforehand.
Establishing the exhaust air connection (exhaust
pipe, 150 mm diameter)
Secure the exhaust pipe to the air pipe connector.
1.
Establish the connection to the exhaust air opening.
2.
Seal the joints.
3.
Connecting to the power supply
Insert the mains plug into the protective contact
1.
socket.
If a fixed connection is required, follow the instruc-
2.
tions in the section
→ "Instructions for the electrical connection",
Page 26.
Fitting the flue duct
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
▶
Note: In circulating-air mode, the flue duct section must
be installed before the circulating-air guide is installed.
You can find information about installing the circulating-
air guide in the installation instructions for the access-
ory.
Screw the flue facing onto the angle bracket at the
▶
side.
Removing the appliance
Remove the flue duct.
1.
Disconnect the appliance from the power supply.
2.
Loosen the exhaust pipe.
3.
Remove the filter.
4.
To avoid causing damage, do not bend the grease
filters.
Loosen the screws for the appliance bracket slightly
5.
but do not undo them fully.
Remove the appliance.
6.
Loosen the angle bracket for the flue duct.
7.
Installation instructions en