Install box in wall cavity in accordance with local building codes, ensuring box is leveled and centered over basin.
watch out wall thickness: min. 7 mm, max. including collar 20mm, max. without collar 25mm
For mains operation remove one of the knockouts on the side of mounting assembly. Route extension cable through opening per
local electrical codes. Extend cable out of mounting assembley (100 mm), loop cable and place in zylindric opening.
Install mud guard to protect wall while fi nishing.
Finish wall and trim mud guard fl ush to wall.
For mains operation place cable, insert solenoid and rotate it clockwise (45°).
Remove crown from outlet. Battery supports function while mains operation.
Route cable from solenoid (1) and mains operation (2) through opening of outlet and mount outlet with 2 screws (3). Optional
mounting of collar, watch out wall thickness (pic. nr. D)
Route solenoid cable under battery pack and insert into holder (1). Note polarity! In case of mains operation connect mains cable (2),
in case of battery operation no connection of mains cable is necessary.
Install battery into holder. Holder drops into body. Place the red cover over the battery.
Attach crown with 2 screws.
start-up sequenze (page 7)
Remove label from sensor window.
Hold hand in front of spout (~5 sec.) until water fl ow starts.
Remove hand after water fl ow has started.
Wait for about 10 seconds.
Faucet ready to operate.
Operation (page 8)
Water-fl ow "on".
Water-fl ow "off ".
electronic functions (page 6)
Battery replacement (page 8)
Remove crown by loosing 2 hex screws located on underside of spout, slide crown down and lift off .
Lift off red cover, change battery. Place battery and red cover in outlet.
Attach crown with 2 screws.
replacing the solenoid/fi lter (page 13)
Remove crown by loosening hex screw located on underside of spout, slide crown down and lift off .
Rotate solenoid assembly counter-clockwise through a 45° angle. Pull solenoid assembley from faucet.
Solenoid/fi lter can be cleaned or replaced at this time.
Insert solenoid assembley at a 45° angle. Rotate solenoid assembley clockwise to align with arrow.
Attach crown with 2 screws.
replace spray insert (page 14)
Remove crown by loosening hex screw located on underside of spout, slide crown down and lift off .
Retrieve spray removal tool located near the spray insert.
Insert spray removal tool into spray slot and pull insert out of faucet.
Install new insert.
Return spray removal tool to storage location. NOTE: This will lock the spray head in place.
Attach crown with 2 screws.
care and cleaning (page 14)
troubleshooting guide (page 11)
technical data
battery
mains operation
operating preasure
Warranty
2 years warranty
6
6 VDC (Typ CRP2)
230 VAC / 6 VDC, <0,3W
0,3 - 10 bar
fl ow rate
max. water temperature
6 l/Min, (2 l/Min. optional)
max. 80°C
74.096.EU15c
EN
pic. nr.
1
2
3
4
5
6
7
8
9
pic. nr.
1
2
3
4
5
pic. nr.
1
2
pic. nr.
1
2
3
pic. nr
1
2
3
4
5
pic. nr.
1
2
3
4
5
6

Publicité

loading