CAUTION: At least two installers are required
due to the weight and size of the hood.
1. Measure from range top to desired hood bottom and
mark line A. (26" minimum from range top) .
2. Plum and mark center line.
3. Mark hood height line B. (18-7/16" from line A)
4. Mark mounting spread from C/L. (8-7/8" on line B)
5. Fasten (2) M4 x 1-1/2" screws into studs on line B but
do not tighten all the way. Note: Wood blocking may
need to be added behind the drywall if no studs are
present. Wall anchors may also be used but check
local codes for compliance. Failure to use suitable
wall anchors and screws to hold the weight of the
hood could result in personal injury or damage to
cooking surface or counter.
6. Remove the (2) aluminum mesh fi lters.
7. Hang hood onto the mounting screws and hand tighten
each screw. (Fig A1) Secure a third M4 x 1-1/2" screw
through inside of hood into wall for extra support. (Fig
A2)
8. Center and attach duct cover mounting bracket to wall
just below the ceiling or soffi t using (2) M4 x 1" screws.
9. Install electrical and duct work. Seal duct work with
aluminum duct tape.
10. Power up hood and check for leaks around duct tape.
11. Place telescopic duct covers onto hood and extend
inner (top) duct cover upwards and secure to duct cover
bracket using (2) M4 x 8 screws. Reinstall mesh fi lters.
* If using hood in recirculating mode you must secure the
air diverter plate onto wall before installing duct work
and duct covers. You will also need to install charcoal
fi lters and brackets. Turn to page 10 for more details.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
8-
B
A
Brackets are
pre-installed
Cable Lock
9
7/8
"
18-
7/16
"
26" min
Fig. A1
Fig. A2

Publicité