Note: Following scheme complies with the standard DIND VDE 0100-701 (VDE 0100-701): 2008-10
The electrical installation has to be carried out in accordance with the country specific standards for low voltage installations, the local electric power
company as well as the country-specific standards.
2. IP area classification
Situation referring to rooms with bathtub
0
6 0
1
0
Area classification in rooms with bathtub or shower
0
area 0
inside the bathtub or shower tray
- above bathtub or shower tray,
height = 2250 mm above finished floor level*
- Showers without shower tray: Distance of
1
area 1
1200 mm from the centre point of the fixed
emersion point of water at the wall or the ceiling,
height = 2250 mm above finished floor level*
area 600 mm from the tub border,
2
area 2
Height= 2250 mm above finished floor level*
3
area 3
remaining room
3. Protection class of Duravit products
Serie
mirrors
2nd floor
IP 44
Darling New
IP 44
Delos
IP 44
DuraStyle
IP 44
Esplanade
IP 44
Fogo
IP 44
Happy D.2
IP 44
Ketho
IP 44
Multibox
-
Onto
IP 44
PuraVida
IP 44
Starck
IP 44
X-Large
IP 44
* or height of highest fixed shower head/ water outlet, depending which is higher
Situation referring to rooms with shower tray
6 0
0
0
6 0
2
3
mirror
cabinets
IP 44
IP 44
0
6 0
IP 44
-
-
IP 44
IP 44
IP 44
IP 44
-
IP 44
IP 44
IP 44
6 0
0
1
2
3
0
protection
Installation of mirrors with lighting and mirror cabinets
class
IP X7
not allowed
Mirror with lighting and mirror cabinets need IP X4, switches within
IP X4
the mirror are allowed, sockets are not allowed.
A IP X4 mirror cabinet with integrated socket have to be installed in
the kind that the socket does not extend into area 1 or area 2.
IP X4
Mirrors with lighting and mirror cabinets with IP X0 are allowed.
IP X0
Socket and switch inside the mirror cabinet are allowed.
0
6 0
1
2
0
Situation referring to showers without tub
or installation of flush fitting shower trays
3
Mirror cabinet with IP 44 may extend into area 2
A socket within the mirror cabinet must be installed
outside the areas
1
21