Elpro S50-T4
GB
IN CASE OF FAILURE OF THE CONTROL BOARD:
- Make sure voltage supply to the electronic board is 230 V ±10% - 50 Hz
- Make sure voltage supply to the electric motor is 230 V ±10% - 50 Hz
- For distances beyond 20 meters increase wire section
- Check power supply 230 V single-phase
- Check fuses
- Check all NC contacts of the control board
- Check that no voltage drop has occurred from the control board to the electric motor
LED DIAGNOSTICS
L1 = Open for pedestrians, normally OFF, do not use
L2 = Photocells, normally ON, it goes off in case of obstruction
L3 = Open, normally OFF, it goes on by pulsing to open
L4 = Close, normally OFF, it goes on by pulsing to close
L5 = Stop, normally ON, it goes off by pulsing to stop
L6 = Radio, normally OFF, it goes on by pulsing the radio
L7 = Normally ON, line voltage and integrity of F1, F2, F3, F4 fuses
L8 = M1 limit switch open, normally ON, off with post 1 in down position
L9 = M1 limit switch close, normally ON, off with post 1 in raised position
L10 = M2 limit switch open, normally ON, off with post 2 in down position
L11 = M2 limit switch close, normally ON, off with post 2 in raised position
L12 = M3 limit switch open, normally ON, off with post 3 in down position
L13 = M3 limit switch close, normally ON, off with post 3 in raised position
L14 = M4 limit switch open, normally ON, off with post 4 in down position
L15 = M4 limit switch close, normally ON, off with post 4 in raised position
DIP-SWITCHES
1 = ON Photocells. Stop in opening
2 = ON Radio. No travel reversing in opening
3 = ON Automatic closing
4 = ON Pre-flashing. Flasher activated
5 = ON Radio step by step, stop in between
6 = do not use
Accessory
Photocells:
Key-switch:
Radio contact:
CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
10 = ON Flasher off in dwell time
11 = ON Close in dwell time after passing between photocells
12 = ON Motor run time max. 90 s. OFF = 18 s
Electrical connections
1
2
NC
NC
24 V - 250 mA Output - max. load:
Photocells
NO and NC contacts to be connected to the
3
4
5
6
respective terminals of the key-switches or
push-buttons.
All possible configurations are described in
NC
the instructions attached to the respective
control accessory
With any NO contact to the two terminals,
the following is performed on each pulse:
3
7
- Opening only: Dip 2 = ON and Dip 5 = OFF
- Travel reversing
Dip 2 = OFF and Dip 5 = OFF
- Step by step: open - stop - close - stop
Dip 2 = OFF and Dip 5 = ON
- No further command accepted on opening.
Stop and reversing performed on dwell time
and closing:
RADIO CONTACT
Dip 2 = ON and Dip 5 = ON
7 = ON deadman (hold-on-switched) control
8 = Traffic lights control (see functions box)
9 = Traffic lights control (see functions box)
9 10
- n° 2 pairs of photocells
- n° 1 radio receiver
9
DIP-SWITCHES
1
2 3
4 5 6 7 8
Dip-switches and LED status of the various functions
DIP-SWITCH N° 1:
ON: Photocells. Stop while opening,
reverse in closing once obstacle is removed
1
OFF: Photocells. No stop while opening, reverse
in closing in case of an obstacle
DIP-SWITCH N° 11:
ON: During dwell time, automatic mode,
(Dip-Switch 3 = ON) after engaging the
11
photocells, it closes after 5 s
OFF: no closing after engaging the photocells
L2 ON = no obstruction. It goes off in case of an
obstacle
L3 OFF = no contact to open, it goes on
whenever a pulse to open is given
L4 OFF = no contact to close, it goes on
whenever a pulse to close is given
L5 ON = stop contact closed, it goes off
whenever a pulse to stop is given
DIP-SWITCH N° 2:
ON: No reversing in opening
2
OFF: Travel reversing on each pulse
DIP-SWITCH N° 5:
ON: Step by step mode with stop in between
5
OFF: Standard functioning
L7 OFF = no RADIO contact, it goes on henever
a radio pulse is given
ON
OFF
910 1112