Elpro S50-T4
GB
Accessory
Beeper, post in motion:
Board power supply:
FUNCTIONS
Description
Automatic / semiautomatic:
Automatic cycle: after a pulse to open, the bollard goes down, it stays stopped as long as the dwell
time lasts, as pre-set by T3 trimmer, and on expiring of such time it goes up automatically.
Semi-Automatic cycle: after a pulse to open, the bollard goes down.
Another pulse is needed to close the gateway.
Deadman control:
Open and Close operations are achieved "by holding a switch on" (no relay
self-holding is involved). Therefore, a physical attendance is required during
the entire cycle of movements until either the button or key is released.
External time clock (optional):
CLOCK: the Elpro S50-T4 controller allows for a normal clock to be connected to it commanding the post
to rise and lower.
Connections: parallel connect the NO contact of the clock to the terminals No. 4 open and No. 3 common,
and set the controller to automatic mode by Dip-Switch n° 3 = ON.
How it works: set the clock to the required opening time. On the pre-set time the post is automatically
lowered ( the indication light emits 2 short flashes followed by a longer pause). Any further
command/pulsing (even by remote control) is not accepted by the system until the time pre-set on the
clock is expired. On expiring of it, and after the pre-set dwell time, the post rises
automatically.
Plug-in traffic lights card (optional):
The power supply of the traffic lights card is independent
from that of the electronic control board:
- 230 V - 50 Hz with an output of 100 W at 230 V ea. lamp.
- 24 V with an output of 25 W each lamp.
- 12 V with an output of 22 W each lamp.
Functioning applies also to traffic lights with 2 lamps, red
and green (Dip Switch 8 = OFF and 9 = OFF).
Functioning logic:
- GREEN Light= post down, gateway OPEN
- RED Light
= post moving or standing,
gateway CLOSED
- YELLOW Light = it switches on before green turns
to red light.
CONTROLLER FOR TALOS M50
ANTI-TERRORISM RETRACTABLE BOLLARDS
Electrical connections
The acoustic device is inside the post and
is on only during the rising and lowering
51 52 53
movements of the post.
BOARD POWER
SUPPLY 400 V ± 10%
50 Hz THREE-PHASE
L1
L2 L3
N
RED
YELLOW
GREEN
Dip-switches and LED status of the various functions
BOARD POWER
SUPPLY 230 V ± 10%
50 Hz SINGLE-PHASE
L
L L
N
JUMPER
!
L-L-L
Dip-switches and LED status of the various functions
DIP-SWITCH N° 3:
3
DIP-SWITCH N° 7:
7
DIP-SWITCH N° 3:
3
DIP-SWITCHES N° 8 and N° 9:
63 64 65 66 60 61
Fuse 1 A
Red
Yellow
Green
(Optional: plug-in traffic lights
card at a 230 V, 24 V or 12 V).
Item Code No. 7282L
11
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic mode
T3
DWELL TIME
1 s - 180 s
ON: Deadman control
OFF: Standard operating mode
ON: Automatic closing
OFF: No automatic closing.
Semi-automatic operating mode
T3
DWELL TIME
1 s - 180 s
Dip-Switch 8 = OFF and 9 = OFF
Yellow turns on for 0 s and after 0 s
OFF
OFF
8
9
red turns on and the post starts
rising immediately
Dip-Switch 8 = ON and 9 = OFF
ON
Yellow turns on for 2 s, then red
OFF
8
9
turns on and after 2 s the post
starts rising
Dip-Switch 8 = OFF and 9 = ON
ON
OFF
Yellow turns on for 6 s, then red
8
9
turns on and after 5 s the post
starts rising
Dip-Switch 8 = ON and 9 = ON
ON
ON
Yellow turns on for 10 s, then red
8
9
turns on and after 7 s the post
starts rising