GB
Elpro S50-T2.EFO
Note well: whenever Elpro S50-T2.EFO is re-powered, wait 10 seconds for the logic to become fully operating again.
NOTE WELL:
- The control panel must be installed in a sheltered, dry place.
- Fit the mains to the control panel with a 0,03 A high sensitivity magneto-thermal circuit breaker.
- Use a multipole cable type BUT FLESSIBILE FG 70R 12x1,5 mm², up to a recommended distance of 20 m maximum between TALOS M50.EFO
and ELPRO S50-T2.EFO.
- For distances longer than 20 m use cables having an adequate section in compliance with the rules of good installation praxis.
- Use 1 mm² section wires for command and safety accessories.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent interference with the microprocessor.
IN CASE OF FAILURE OF THE CONTROL BOARD:
- Make sure voltage supply to the electronic board is 230 V ±10% - 50 Hz
- Make sure voltage supply to the electric motor is 230 V ±10% - 50 Hz
- For distances beyond 20 meters increase wire section
- Check power supply 230 V single-phase
- Check fuses
- Check all NC contacts of the control board
- Check that no voltage drop has occurred from the control board to the electric motor
DIAGNOSTIC LEDS
L1 = pedestrian opening, normally OFF, alight when a pedestrian open pulse is given
L2 = photocells or loop, normally ALIGHT, if obstructed light goes off
L3 = open, normally OFF, alight when an open pulse is given
L4 = close, normally OFF, alight when a close pulse is given
L5 = stop, normally ON, it goes off when a stop pulse is given
L6 = radio, normally OFF, alight when a radio pulse is given
L7 = normally ON, mains voltage and fuse integrity F1, F2, F3, F4
L8 = limit switch open M1, normally ON, it goes off when the post is in down position
L9 = limit switch close M1, normally ON, it goes off when the post is in up position
L10 = limit switch open M2, normally ON, it goes off when the post is in down position
L11 = limit switch close M2, normally ON, it goes off when the post is in up position
Accessory
Board power supply:
Photocells
or loop detectors:
Pedestrian opening:
CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
Electrical connections
BOARD POWER SUPPLY
400 V ± 10%
50 Hz THREE-PHASE
L1
L2 L3
N
1
3
Photocells or
loop detectors
By a pedestrian command only the bollard
connected to M1 is lowered. The pedestrian
58
3
opening function cannot be performed
during the first operating cycle after a power
failure.
PEDESTRIAN
OPENING
CONTACT
DIP-SWITCHES
1 = ON Photocells or loop stop while opening
2 = ON Radio no reversing while opening
3 = ON Automatic closing
4 = ON Pre flashing activated
5 = ON Radio step by step stop in between
6 = ON Pedestrian opening motor M1 only one post operating
7 = ON Deadman control
8 = Traffic lights (see functions)
9 = Traffic lights (see functions)
10 = ON No lamp on during dwell time
11 = ON Close on dwell time after passage through photocells or over the loop
12 = ON Max working time 90 s. OFF = 18 s
BOARD POWER SUPPLY
230 V ± 10%
50 Hz SINGLE-PHASE
L
L L
N
JUMPER
!
L-L-L
9 10
24 Vac - 250 mA Output
max load:
- n° 2 pairs of photocells
- n° 1 radio receiver
9
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
Dip-switches and LED status of the various functions
DIP-SWITCH N° 1:
ON: Photocells. Stop while opening,
reverse in closing once obstacle is removed
1
OFF: Photocells. No stop while opening, reverse
in closing in case of an obstacle
DIP-SWITCH N° 11:
ON: During dwell time, automatic mode,
(Dip-Switch 3 = ON) after engaging the
11
photocells, it closes after 5 s
OFF: no closing after engaging the photocells
L2 ON = no obstruction. It goes off in case of an
obstacle
DIP-SWITCH N° 3 and N° 6 both on ON:
ON: automatic closing
OFF: No automatic closing.
3
Semi-automatic closing
ON: pedestrian opening motor M1
6
OFF: standard operation
T2
DWELL
TIME
from 1 to 180 s