Télécharger Imprimer la page

fadini Elpro S50-T2.EFO Mode D'emploi page 10

Publicité

Les langues disponibles

Les langues disponibles

GB
Elpro S50-T2.EFO
Accessory
Key-switch:
Radio contact:
24 V - 3 W max
Light indicating
bollard in motion:
Motors:
Limit switches:
Beeper, post in motion
and/or external flasher:
Signalling LED lights:
CONTROLLER FOR TALOS M50.EFO
ANTI-TERRORISM RETRACTABLE BOLLARDS
Electrical connections
NO and NC contacts to be connected to the
respective terminals of the key-switches or
3
4
5
6
push-buttons.
All possible configurations are described in
NC
the instructions attached to the respective
control accessory
With any NO contact to the two terminals,
the following is performed on each pulse:
3
7
- Opening only: Dip 2 = ON and Dip 5 = OFF
- Travel reversing
Dip 2 = OFF and Dip 5 = OFF
- Step by step: open - stop - close - stop
Dip 2 = OFF and Dip 5 = ON
- No further command accepted on opening.
Stop and reversing performed on dwell time
RADIO CONTACT
and closing:
Dip 2 = ON and Dip 5 = ON
Light on = post down, gateway cleared
Light off = post up, gateway closed
3
8
Flashing 0,5 s (fast) = post moving up
Flashing 1 s (normal) = post moving down
With an external time clock: 2 short flashes
followed by a longer pause
16 17 18
19 20 21
M1
Bollard 1
Bollard 2
MOTOR 1
MOTOR 2
11
12
14
15
+ -
55 56
The acoustic device is inside the post and is
on only during the rising and lowering
movements of the post.
51 52 53
It is possible to connect an external flashing
lamp to the bollard in addition to the
incorporated LED lights. The flasher will be
on
during
movements and during the dwell time (if
pre-selected).
230 V - 100 W max
Output for the LED lights that are always on
51 52 53
blinking during the rising and lowering
movements of the post and with the post in
standing position. They go off with post in
down position.
M2
the
rising
and
lowering
10
Dip-switches and LED status of the various functions
L3 OFF = no contact to open, it goes on
whenever a pulse to open is given
L4 OFF = no contact to close, it goes on
whenever a pulse to close is given
L5 ON = stop contact closed, it goes off
whenever a pulse to stop is given
DIP-SWITCH N° 2:
ON: No reversing in opening
OFF: Travel reversing on each pulse
2
DIP-SWITCH N° 5:
ON: Step by step mode with stop in between
5
OFF: Standard functioning
L7 OFF = no RADIO contact, it goes on henever
a radio pulse is given
DIP-SWITCH N° 12:
ON: Motor run time max 90 s
12
OFF: Motor run time max 18 s
T1
MOTOR RUN TIME
DWELL TIME
1 s - 22 s
L8 ON = it goes off with post 1 down
L9 ON = it goes off with post 1 up
L10 ON = it goes off with post 2 down
L11 ON = it goes off with post 2 up
DIP-SWITCH N° 4:
ON: Pre-flashing with beeper
OFF: No pre-flashing with beeper
4
DIP-SWITCH N° 10:
ON: Flasher and/or beeper. Deactivated during
dwell time, automatic mode
10
OFF: Flasher and/or beeper. Activated during
dwell time, automatic mode
T2
1 s - 180 s

Publicité

loading