PARAMETER INFORMATION
To send parameter information:
Pin1234, PCxx then value to set, (send)
'C' indicates the lift shaft number (1, 2, 3 or 4)
To read parameter information:
Pin1234, PCxx? (send)
Note: Use a question mark '?' when you are reading parameters.
The table below indicates all the parameters which can be set on the DAU:
CMD
PC01
PC02
PC03
PC06
PC08
PC09
PC10
PC11
PC12
PC13
PC14
PC15
PC16
PC17
PC18
PC19
PC21
PC22
PC23
PC24
PC25
PC26
PC27
PC28
(1=Spanish;2=Portuguese;3=Italian;4=English;5=German;6=French)
PC29
PC32
PC33
*If alarm Acknowledgment is on, Operator must press "0" to acknowledge the alarm
**The DAU can use up to 6 simultaneous languages, each digit being it's sequence order.
Description
End of Alarm (EOA)
Reset of Alarm (ROA)
Firmware Version
Device Status
Alarm call bypass filter time
Reset to Factory Default
Reboot Digital Audio Unit
Alarm Button Countdown timer (seconds)
Alarm Filter Input (0=Off ; 1=On)
Cancel alarm by pressing alarm button (0=Off ; 1=On)
Wait for Alarm Acknowledgment (0=Off ; 1=On) *
Wait for End of Alarm EOA (0=Off ; 1=On)
Privacy Mode
Alarm Button Type (0=N/O; 1= N/C)
Maintenance Alarm Button Type (0=N/O; 1= N/C)
EOA Button Type (0=N/O; 1= NC)
LED Mode (0=Full ; 1=EN81-28)
Alarm Call Retry Attempts
Maintenance Call Retry Attempts
Lift Car Microphone Volume
Lift Car Speaker Volume
Lift Car Announcement Volume
Floor voice synthesis
Language **
Time between alarm calls (in seconds)
Extended Address
Battery check enabled
Avire Ltd
Unit 1, The Switchback
Gardner Road
Maidenhead
Berkshire
SL6 7RJ, UK
T:
01628 540100
F:
01628 621 947
E:
sales.uk@avire-global.com
W:
www.avire-global.com
Default value
-
-
-
-
10
-
-
3
1
0
1
0
1
0
0
0
1
5
3
5
5
5
1
400000
0
00
1
Fig 7