OPTIONS SELECTOR (SW1)
SW1
FUNCTION
1
CAN1 ID
2
3
Picto. Vo
CAN 1 Ω
4
LED INDICATORS
There are two LED indicators on the CAN DAU LPBus; green and yellow. The following
table describes their operation.
Yellow LED
OFF
ON
ON
OFF
OFF
PROGRAMMING THE DAU
The CAN DAU LPBus is configured via the Digital Communication Platform (DCP). The
DCP can be configured remotely via the Avire Hub or via SMS.
1) THE AVIRE HUB
+
All settings can be configured remotely via the Avire Hub
+
The link to the Avire Hub is hub.avire-global.com Please contact your local sales
office to get access to the Avire Hub.
2) SMS COMMANDS
+
All DAU parameters can be remotely configured via SMS.
+
Each SMS message should begin with 'Pin1234' which is the access code to read or to
make any changes to the configuration of the DCP.
+
You can modify or check several parameters in each SMS by separating them with
commas ","
In a system with more than one lift car you need to select the lift
shaft for each CAN DAU LPBus. The below table shows how you
can set the ID for each DAU.
24V
12V
Activates the CAN End of Line (EOL) for the CAN 1 connector
Green LED
OFF
OFF
ON
ON
Quick Flashing
DESCRIPTION
FUNCTION
End of alarm or Device on standby
Alarm started, communication is established
OR End of voice communication
Start voice communication
Audio module communication established
External audio module communication
established
Fig 4
Fig 5
4