6.3
Tabelle System Kommandos
Restore factory setting 0X02
Teach-in position A
0X02
Teach-in position B
0X02
Transfer switching
0X02
positions
Save parameters
0X02
6.4
Tabelle Fehlercodes
Communication error
(Checksum, ...)
Length of written SPDU is wrong
Reading an unimplemented SPDU
Writing to an unimplemented SPDU
Reading Index 2
Writing to a read only SPDU
Writing an unimplemented System Command
Distance between two tought points too small
Written parameter out of defined range
6.5
Tabelle Werkseinstellungen
Switching points work
Nominal value
quality parameter
Output Delay Function
Output Delay Time
fr_BA_FNDx14_FHDx14_IO.doc
10.04.2013/hem
0X82
Restores all original factory settings of the sensor
0XA0
Teach-in of switching point A. The measured distance is written into the interim Teach in
position register.
0XA1
Teach-in of switching point A. The measured distance is written into the interim Teach in
position register.
0XA2
Transfer of the teach-in positions from the interim to the working register.
0XE0
Save all parameters in Flash memory
0x10
0x00
Communication error, No details
0x10
0x00
Communication error, No details
0x80
0x11
Device error, Index not available
0x80
0x11
Device error, Index not available
0x80
0x23
Device error, Access denied
0x80
0x23
Device error, Access denied
0x80
0x23
Device error, Access denied
0x80
0x40
Device error, Interfering parameter
0x80
0x30
Device error, Parameter value out of range
0X40
Switching point A: 50mm
Switching point B: 65535 (entspricht "Not valid")
0X65
7
0X71
0 = No delay
0X72
1 (ms)
13/14
Baumer Electric AG
Frauenfeld, Suisse