6
Assemblage des paramètres
Table des paramètres général
6.1
General information on sensors
Vendor Name
0X10
18
Product Name
0X12
22
Product ID
0X13
8
Serial Number
0X15
4
Firmware Revision
0X17
8
Application Specific
0X18
8
Name
6.2
Table des paramètres usage
Teach-in and switching points
Switching points
0X40
4
work
Teach-in positions
0X41
4
interim
Sensor functions
Teach function
0X60
1
Nominal value
0X65
1
quality parameter
Quality parameter
0X66
1
Output functions
Output delay
0x71
1
function
Output delay time
0x72
2
fr_BA_FNDx14_FHDx14_IO.doc
10.04.2013/hem
String
String
String
String
String
-
Switching point A (HB, LB)
Switching point B (HB, LB)
Teach-in Position A (HB, LB)
Teach-in Position B (HB, LB)
0 = One point Teach-in
(Reference position)
2 = Two point Teach-in
(ON/OFF-position)
Byte 0 (Subindex 1)
0 = no delay
1 = on delay
2 = off delay
3 = minimum pulse
4 = single shot positive edge
5 = single shot negative edge
Byte 1...2, time in 1ms
12/14
ASCII
R
"Baumer Electric AG" for all sensors
ASCII
R
Corresponds
description
ASCII
R
Corresponds with Baumer article number
ASCII
R
Baumer P-Code
ASCII
R
Baumer Firmware Revision
-
R/W
8 Byte at customer disposal
50...400
R/W
Distance information on switching points,
calculated from the information on Teach-
in position interim
50...400,
R
Distance information on Teach-in position
65535
0,2
R/W
Selection of Teach mode
1..8
R/W
Provided the internal quality parameter
drops below this threshold the switching
output is set.
1..8 or 255
R
0...5
R/W
Choose delay funciton
0...1000
R/W
Delay time
with
Baumer
article
Baumer Electric AG
Frauenfeld, Suisse