OPERATION
NOTE: Leaking water systems may cause the system to cycle more than expected. This is due to the
unit turning on when the outlet pressure drops below the preset discharge pressure (factory-set at 40
psi/2.8 bar). Continuous running or a high number of starts and stops will not hurt the controller, pump,
or motor. The issue should still be fixed, if possible, to eliminate an increase in power usage of the sys-
tem.
Flow Direction
When mounted vertically on a wall, the unit comes standard with the flow direction
from left to right. In this orientation, the status display and the label (1) is in front.
To change the flow direction to right to left:
1.
Do not apply power to system.
2. Remove two pump mounting bolts (2).
3. Rotate the pump 180 degrees.
4. Re-install the two mounting bolts.
•
There are four mounting lugs on the unit, so rotate the pump in 90° incre-
ments (in relation to the mounting bracket) if desired.
To rotate the control cap:
1.
Remove six control cap screws (3).
2. Rotate the cap in 60 degree increments to place the status display in a viewable orientation.
NOTE: Be careful when rotating the control cap as there is an electrical cable attached to it.
Flow Direction
3
1
OPERATION
2
9