Télécharger Imprimer la page

Dustcontrol TPR 53 37 kW Notice Originale page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
Installation
C. The pump should be installed on a concrete pad. A second pump may be moun-
ted on the top of the fi rst pump.
1.
Ancor the pump to the concrete pad.
2. Remove the pump covers and assemble the
protection screen skirt if this is required (A).
3. Connect the ducting to both the inlet and the
outlet. Do not start the pump without having it
connected to the ductwork.
4. The pump inlet should always be connected to a
separator with a fi lter unit (B). The pump cannot
tolerate contaminated airfl ow .
5. Extra silencing can be installed if the outlet
sound level is to be lowered from appro-ximately
75 dB(A) to approximately 62-64 dB(A). See Ac-
cessories on page 18.
6. If the outlet is vertical, and exposed to the
elements, rain protection should be installed (C)
Exhaust air can be very hot, up to 150 OC.
2022-01-18
7.
Electrical connections may only be performed
by a certifi ed electrician. A separate locka-
ble disconnect should be installed where it
is readily accessible and within view of the
pump.
8. Thermal overload protection must be installed to
validate the warranty.
9. The control panel must be equipped with an
overload protection that should be adjusted and
tested by a certifi ed electrician. Check for correct
motor rotation.
TPR 53, 37 kW - 16
Art nr 94115-B

Publicité

loading

Ce manuel est également adapté pour:

94115-b