NOTE:
1. The sealing strip should be pasted along the edge of the machine. i
2. Please peel the striping layer on the sealing strip gradually while pasting.
3. Paste from the bottom of the machine first.
4. The position of the corner should be pasted as shown in j
5. Improper pasting may cause extra noise.
10. Lift the unit onto the wall, align the hanging holes with the hooks on the
hanging rail and gently rest the unit into place. At the same time, slide the
drain pipe through the drainage hole. If the wireless controller (Available
separately) has been purchased, it should then be installed, and connected. k
NOTE: The end of the external water pipe must be placed in an open space or
drain. Avoid damage or constriction to the drainage pipe to ensure the unit
drains.