It is dangerous to alter the specifications or attempt to modify this product in any way.
ELECTRICAL SUPPLY
PERFORMANCE
*IEC 61591 method for cooker hoods in evacuation mode - ** IEC 61591 method with free delivery - ***IEC 60704-2-13 method
This appliance conforms to BS.800:1988 and EEC Directive No. 78 308 regarding suppression of radio
and television interference.
Note: CE Marking certifies that this appliance complies with the requirements laid
down in EEC directive 89:336 (Electromagnetic compatibility) and subsequent
modifications and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTION

THIS APPLIANCE MUST BE EARTHED

ELECTRICAL REQUIREMENTS

Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local Electricity
Board regulations. For your own safety this should be
undertaken by a qualified electrician e.g. your local
Electricity Board, or a contractor who is on the roll of
the National Inspection Council for Electrical
Installation Contracting (NICEIC).
ELECTRICAL CONNECTION
Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on the
rating plate inside the cooker hood.
This appliance is fitted with two 3 core mains cable
and must be permanently connected to the electricity
supply via two double-pole switch having 3 mm minimum
contact gap on each pole. Two Switched Fuse
connection units to BS.1363 Part 4, fitted with a
3 Amp. fuse are a recommended mains supply
connection accessory to ensure compliance with
the safety requirements applicable to fixed wiring
intructions.
VOLTAGE: (50Hz)
POWER CONSUMPTION:
FAN MOTOR:
LIGHT BULB:
3 x 20W
SPEEDS
CAPACITY m
3
/h*
CAPACITY m
3
/h**
PRESSURE PA
NOISE LEVEL dBA***
The wire which is coloured green and yellow must be
connected to the terminal which is marked with the
letter 'E' or by the earth symbol
and yellow.
The wire which is coloured blue must be connected
to the terminal which is marked with the letter 'N' or
coloured black.
The wire which is coloured brown must be connected
to the terminal which is marked with the letter 'L' or
coloured red.
410W
350W
Electronic
770-875
930-1050
68-39
The wires in this mains
lead are coloured in
accordance with the
following code:-
Green & Yellow
Earth
Blue
Neutral
Brown
Live
As the colours of the wires
in the mains lead of this
appliance may not
correspond with the
coloured markings
identifying the terminals in
your connection unit,
proceed as follows:-
or coloured green
230V
60W
340