symptom
Pilot lights
Wiring / connection.
Stops sparking / pilot
remains lit but burner
will not turn on.
Wiring harness.
Exhaust fumes smelled
Appliance is spilling
in room, headaches.
White / grey fi lm forms.
Sulphur from fuel is being depos-
ited on glass, logs or combus-
tion chamber surfaces.
Flames are very ag-
Door is ajar.
gressive
Venting action is too great.
TDS60-1 ONLY
Main burner fl ame is a
Blockage in vent.
blue, lazy, transparent
fl ame.
TDS60-1 ONLY
Compromised venting.
Main burner goes out;
Vent recirculation.
pilot goes out.
Main burner and pilot
Venting is spilling.
cycles on and off.
TS60-1 ONLY
problem
-
Inspect all wires, ensure good tight connections. Verify that all wiring
is installed exactly as specifi ed.
-
Inspect the wiring harness and verify the harness is tightly connected
to the module. Verify that all wires are connected in the right order.
see "wiring diagram" section.
Check all seals.
Check if exhaust is re-entering through an open door or window.
-
Clean the glass, see "care of glass" section.
-
DO NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass may become
permanenttly marked.
-
Tighten door clamps (if applicable).
-
Restrict vent exit with restrictor plate. See "restricting vents" section
(if applicable).
-
Remove blockage. In extreme conditions, ice buildup may occur
on the terminal and should be removed. To minimize this from
happening again, it is recommended that the vent lengths that pass
through unheated spaces (attics, garages, crawl spaces) should
be wrapped with an insulated mylar sleeve. Prevent sleeve from
sagging. Contact your local authorized dealer for more information.
-
Check venting system parameters (seal, length, rise, etc.).
-
Check joint seals and installation.
-
Test with spill switch bypassed. Replace if defective.
-
Check for vent blockage.
troubleshooting
test solution