3.
handlIng
3.1 n
ose
observed! Only use noses which are in perfect condition.
Check nose before use. The nose must be centred and
secured with the lock nut.
V
ery shArP BlAde
3.1.1 c
/c
hAnging
onnecting the nose
Screw nose to pneumatic drive, align it, and secure it with
the lock nut. After connecting, press the grease can but-
ton two to three times. If you cannot completely screw in
the nose, turn the ring cutter slightly.
V
ery shArP BlAde
3.2 t
ools
Use only clean tools!
3.2.1 c
/
onnecting
detAching
Use an allen key to loosen the setscrews.
/ o
PeratIon
Only use SUHNER noses.
The instructions issued by
the manufacturer must be
!
!
/
the BlAde
Remove the blade housing by drawing it towards you.
Detach the blade from the blade housing. To connect
the blade, follow the above instructions in reverse order.
Tighten the screws with max. 1.5 Nm. After connecting,
press the grease cup button two to three times.
V
ery shArP BlAde
3.3 w
orKing instructions
Machine still runs out when the valve lever
is released! On compressed air failure the
valve lever must be released!
4. s
ervIce
4.1 P
reVentiVe mAintenAnce
The machine must be cleaned
daily. When cleaning, examine all
parts for wear, fracture, cracking,
or other signs of damage. Without a tool clamped in
check no-load speed periodically and after each mainte-
nance. Even if the machine still operates perfectly, the
motor should be removed, cleaned and the four slides
checked for wear by a specialist after approx. 300 to 400
operating hours.
V
ery shArP BlAde
!
/ m
aIntenance
!
21