Reset of the measurement
To reset the measurement count, press the R key for at least three seconds.
Loading factory data
To load the factory data, turn the instrument off and on again; when the MZ logo appears
press the R button and hold it until this screen appears:
Release the R button and press it again to confirm default loading otherwise press C to exit
without loading anything.
This function allows you to recall the original data, set in the factory, deleting the
stored settings; use this command only in case of incorrect programming.
Troubleshooting
FAULT
Though UP or DOWN
buttons are pressed, the
instrument doesn't
receive any signal from
the magnetic sensor for
more than 4 seconds.
CC011
CAUSE
Check the sensor electric connections.
Check if sensor operates properly. If not, replace it.
Check the position of sensor and magnet on gipsy
and their distance (3 mm).
Check the operation of electric installation or anchor
windlass.
CORRECTIVE ACTION
30
English
Rev. 01 – 2024