Specifications
Model
Item
No.
No.
Listings
8-CIM
508057
UL/CSA
8-CIM
508058
UL/CSA
8-CBM
508257
UL/CSA
8-CIA
508157
UL/CSA
8-CIA
508158
UL/CSA
8-CBA
508357
UL/CSA
Continuous Duty Rated — "Little Giant Wastewater pumps are rated continuous duty as long as they are run within the published ratings for these pumps."
CIM/CBM – Manual
CIA/CBA – Automatic
FL OW - LITERS/MINUT E
FL OW - GALL ONS/MINUTE
www.LittleGiantPump.com
8 Series
Running
HP
Volts
Amps
Watts
4/10
115
10
830
4/10
115
10
830
4/10
115
10
830
4/10
115
10
830
4/10
115
10
830
4/10
115
10
830
All models are 60 Hz.
Performance (GPM @ Head)
Shut Off
5'
10'
15'
Feet
54
42
26
22.9
54
42
26
22.9
54
42
26
22.9
54
42
26
22.9
54
42
26
22.9
54
42
26
22.9
Construction
Epoxy coated cast iron (CI) or cast bronze
Motor Housing
(CBM and CBA models)
Impeller Material
Polypropylene
Impeller Type
Non-clog
Volute
Polypropylene
Power Cord
18-3, SJTW
Mechanical Shaft Seal
Nitrile with carbon and ceramic faces
Fasteners
Stainless steel
Shaft
CRS
Bearings
Upper & lower: Sintered, iron, flanged sleeve
Pwr. Cord
Weight
Dimensions
PSI
(ft.)
(lbs.)
(H x L x W in.)
9.9
10
18.80
6.00 x 9.50 x 8.50
9.9
25
19.80
6.00 x 9.50 x 8.50
9.9
10
21.00
6.00 x 9.50 x 8.50
9.9
10
19.00
6.00 x 9.50 x 8.50
9.9
25
20.30
6.00 x 9.50 x 8.50
9.9
10
21.30
6.00 x 9.50 x 8.50
PO Box 12010 • Oklahoma City, OK 73157
Phone: 800.701.7894 • Fax: 800.701.8046
E-mail: customerservice@littlegiant.com
Form 995209 — 03/2003