BATTERY CHECK HIGH
VOLTAGE
BATTERY VOLTAGE CELL
LOW
BATTERY VOLTAGE CELL
HIGH VOL
BATTERY VOLERR CELL
CONNECT
TEMP OVER ERR
CONTROL FAILURE
REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
INPUT VOLT ERR
VOL SELECT ERR
BREAK DOWN
Voltage detected over the
battery voltage supposed to
be plugged in
The voltage of one cell is
too low
One cell has a too high
voltage
Connection / voltage error
Temperature is too high
Voltage ( input / output /
check) failure
Polarty of battery (output) is
inverted
Battery connector is
unplugged or
malfunctionning.
Short Circuit detected
Input power supply voltage
error
The voltage you have setup
is not matching the voltage
detected by the charger for
the battery.
Hardware / software error
Error messages
Check the number of cells and correct if necessary
Check the battery and battery balance. If voltage too low please
contact the battery manufacturer to ask about process to handle.
Check the battery balance and inspect carefully the battery to search
for any physical damage. Do not insist on charging and do not launch
a discharge process without contacting your battery manufacturer / distributor first.
Check all connectors and battery integrity
Stop any process and wait for the battery to cool down before
checking the battery.
Check battery, input power supply / battery and contact imediatly
your distributor for any assistance.
Check connection
Check all wires and connectors, and battery.
Check all cables / connectors and the balance connector of battery.
Check the power supply, in case of use of a battery car, it might be
discharged or you might need to setup a lower input voltage low
limit. Contact your distributor for any advise or for power supply
check.
Check the battery and the connections, and specify correct voltage / number of cells. For Lithium
Batteries, if the voltage can not be
detected correctly by the charger, please contact the battery
manufacturer / distributor
Stop any process, disconnect the charger from power supplly and
disconnect any battery attached to the charger. Contact your
distributor technical support.