Latching force, adjustable, position 1
Latching force, adjustable, position 2
Type of the fixing screws
Tightening torque of the fixing screws, minimum
Tightening torque of the fixing screws, maximum
Données mécaniques - Distances de commutation selon EN IEC 60947-5-3
Switch distance, typical
Assured switching distance "ON" S
Assured switching distance "OFF" S
Données mécaniques – technique de connexion
Length of sensor chain, maximum
Note (length of the sensor chain)
Note (series-wiring)
Termination
Données mécaniques - Dimensions
Length of sensor
Width of sensor
Height of sensor
Conditions ambiantes
Degree of protection
Ambient temperature
Storage and transport temperature, minimum
Storage and transport temperature, maximum
Relative humidity, maximum
Note (Relative humidity)
Resistance to vibrations
Restistance to shock
ao
ar
25 N
50 N
2x M6
6 Nm
7 Nm
2 mm
1 mm
20 mm
200 m
Cable length and cross-section change the voltage drop dependiing
on the output current
Unlimited number of devices, oberserve external line fusing, max. 31
devices in case of serial diagnostic SD
Connecteur M12, 8 pôles, codage A
120 mm
87,5 mm
35 mm
IP67
IP69
IP66
+0 ... +60 °C
-10 °C
+90 °C
93 %
sans condensation
non givrant
10 ... 150 Hz, amplitude 0,35 mm
30 g / 11 ms
7-32