Télécharger Imprimer la page

schmersal AZM300B-I2-ST-1P2P-A Instructions Pour Fonctionnement Et Montage page 6

Publicité

Gross weight
Données générales - Caractéristiques
Power to lock
Actuator monitored
Latching
Manual release
Short circuit detection
Cross-circuit detection
Series-wiring
Safety functions
Integral system diagnostics, status
Number of actuating directions
Number of fail-safe digital outputs
Classification
Standards
Classification de sécurité - Fonction d' interverrouillage
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Données mécaniques
Mechanical life, minimum
Note (Mechanical life)
Angular misalignment between solenoid interlock and actuator,
maximum
Holding force F
in accordance with EN ISO 14119
Zh
Holding force F
, maximum
max
550 g
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
3
2
EN ISO 13849-1
EN IEC 61508
e
4
5,20 x 10⁻¹⁰ /h
4,50 x 10⁻⁵
3
20 Year(s)
1 000 000 Operations
Si utilisé comme butée de porte: > 50.000 manoeuvres (pour
protecteurs ≤ 5 kg et vitesse d'attaque ≤ 0,5 m/s)
2 °
1 150 N
1 500 N
6-32

Publicité