GETTING STARTED WITH THE MACHINE
LUBRICATION
Always use of an air line lubricator with these tools. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed
air network, inject 1/2 to 1cm3 through the machine's inlet connection.
3
Model
Chuck capacity
mm
V.D100QR
10
Model
Rated speed
rpm
V.D100QR
1800
* k = measurement uncertainty in dB * k = measurement uncertainty in m/s²
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - 91 420 MORANGIS - FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE PRODUCT
V.D100QR – FACOM 10 MM PNEUMATIC DRILL
- IS IN CONFORMITY WITH THE «MACHINERY" DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-3: 2012
The undersigned is responsible for compilation of the technical fi le and makes this declaration on behalf of Facom.
NU-VD100QR_0416 ok.indd 8
1
4
Motor power
rating
Pressure dB(A)
kW
k*
0,5
83
3
Air consumption
Working
pressure
l/min
bar
113
6,2
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
2
Noise level
Power dB(A)
Pressure dB(C)
k*
90
3
130
Weight
Dimensions
kg
mm
1
195x42x151
Markus Rompel
20.03.2016
Director Engineering
Vibrations level
m/s
2
k*
k**
3
0,4
0,24