Télécharger Imprimer la page

Schumacher Electric SP1296 Guide D'utilisation page 8

Publicité

Les langues disponibles

Les langues disponibles

8.3 USING AN EXTENSION CORD
The use of an extension cord is not recommended. If you must use an extension
cord, follow these guidelines:
• Pins on plug of extension cord must be the same number, size, and shape as
those of plug on charger.
• Ensure that the extension cord is properly wired and in good electrical condition.
• Wire size must be large enough for the AC ampere rating of charger, as specified:
Length of cord (feet)
AWG* size of cord
*AWG-American Wire Gauge
9. ASSEMBLY INSTRUCTIONS
9.1 Remove all cord wraps and uncoil the cables prior to using the battery charger.
10. FEATURES
11. CONTROL PANEL
LED INDICATORS
CLAMPS REVERSED/BAD BATTERY (red) LED flashing:
The connections are reversed.
CLAMPS REVERSED/BAD BATTERY (red) LED lit: The charger has
detected a problem with the battery. See Troubleshooting for more information.
(Yellow/orange) LED lit: The charger is charging the battery.
CHARGED/MAINTAINING (green) LED lit: The battery is fully charged
and the charger is in maintain mode.
NOTE: See Operating Instructions for a complete description of the charger modes.
25
50
18
18
1
3
4
• 8 •
100
150
18
16
1. Charging status LEDs
2. 12V accessory plug
(quick-connect)
3. Battery clamps (quick-connect)
4. Ring connectors (quick-connect)
2

Publicité