• MAINTENANCE AFTER USE:
If you do not plan to use the device for an extended period:
1. Remove the rubber plug from the drain opening (bottom of the unit) to drain the unit.
2. During ½ day and in good weather, operate the appliance in VENTILATION mode only so that
it dries inside and prevents it from molding.
3. Switch off and unplug the appliance.
4. Clean the air filter and reinstall it.
5. Remove the air hoses and store them carefully. Close the hole tightly.
6. Always unplug the machine from the power outlet before putting it away.
➢ TECHNICAL SPECIFICATIONS :
Model :
Supply voltage :
Power consumption :
Cooling capacity :
Refrigerant gas:
Type of fuse used:
Discharge pressure:
Suction pressure:
Maximum tolerated
pressure
Protection class:
ENERGY EFFICIENCY CLASS
NOMINAL COOLING CAPACITY (kW)
NOMINAL ABSORBED COOLING CAPACITY (kW),
NOMINAL ENERGY EFFICIENCY COEFFICIENT,
ENERGY CONSUMPTION (kWh / 60min),
The energy consumption of 2.1 kWh for 60 minutes, based on results obtained under standardized
test conditions. The actual energy consumption will depend on the conditions of use and the location
of the device.
ACOUSTIC POWER LEVEL (dB)
IN "COOLING" MODE L
AMCLI180E
230V ~50 Hz
2026W
5270W
R290 / 300g
T3.15A, AC250V
1.8 MPa
0.6 MPa
3.0 MPa
Class I
BRAND
REFERENCE
P
refrigeration
rated
P
EER
EER
rated
Q
SD
REFRIGERANT
WA
EN-24
AMSTA
AMCLI180E
A
5.2
2.1
2.6
2.1
65
R290 (0.3 kg)