2-8. 115 Volts AC Duplex Receptacle
2-9. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC).
1
60 Hz
200
230
105
91.2
150
125
4
6
116 (35)
103 (31)
271 (83)
6
6
Y Turn Off power before con-
necting to receptacle.
1
115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 4-2).
Power output is shared between
this receptacle and the Remote 14
receptacle (see Section 2-7).
460
575
220
45.6
36.4
88.2
70
50
125
8
10
6
284 (87)
99 (30)
8
10
6
Ref. ST-152 973-A
50 Hz
380
415
51
46.8
80
70
8
8
194 (59)
232 (71)
8
8
S-0092J
OM-318 Page 13