PE 6001
PE 6000M
MOBILE SCISSOR LIFT DUAL CYLINDER LOW RAISE 3T
MOVABLE ELECTRO HYDRAULIC LIFT
LIFT TEST:
Turn on the machine with the MAIN POWER button.
Press the «UP» button, pay attention to the synchronization and the lifting fluidity.
Check that there is no leakage of oil.
During the test of the lift, no person and no object and / or material must be located near
the two sides and below the lift. If an anomaly occurs, press the emergency button to stop
the lift immediately. After removing the obstacles, repeat the test.
LOAD TEST:
Bring the vehicle, with a weight not exceeding the maximum lifting capacity, on the plat-
form.
Put the rubber pad on the platforms.
Press the 'UP' button, raise the platforms and pay attention to the synchronization and
the fluidity of the lift.
Check and make sure that there is no leakage on the hydraulic circuit. If an anomaly
occurs, press the emergency button to stop it immediately. After resolving issue, repeat
the test.
When starting the load test no person or material must be beneath or close to any of the
moving parts of the lift.
If a failure occurs, press the «EMERGENCY STOP» button to stop it immediately.
After removing obstacles, repeat the test.
44
44
figture 23