Télécharger Imprimer la page

Blaupunkt 5IX94290 Prescriptions De Montage Et Mode D'emploi page 43

Publicité

Les langues disponibles
  • FR

Les langues disponibles

L
L2
L1
1
The induction hob is composed of 2 modules, each one can absorb 3.7kW max.
Scheme 1: for 1 phase (220-240V~ 1N), total power absorbed 7,4kW (7,4kW for phase)
Scheme 2: for 2 phase (380-415V~ 2N), total power absorbed 7,4kW (3,7kW for phase)
The total rated power of the product is 8,8kW (1,4kW+3kW+3kW+1,4kW)
Electrical connection diagram
220-240V
N2
3
4
N1
2
5
1
N
L
220-240V
220-240V
L
1
2
L2
3
L1
2
1
2
N
N2
4
N1
5

Publicité

loading