CONNECTING TO GAS SUPPLY
THE USE OF A TYpE OF GAS AND/OR OF A pRESSURE DIFFERENT FROM THOSE
pRESCRIbED bY SMEV, MAY CAUSE IRREGULAR OpERATING CONDITIONS OF
THE AppLIANCE; FOR THIS REASON, SMEV DECLINES ANY RESpONSIbILITY
ORIGINATING FROM INCORRECT USE OF THE AppLIANCE ITSELF.
This appliance runs off the following gas at the corresponding supply pressures. The gas category of the appliance is
given on the specifications label affixed to the appliance.
PRESSURE
INLET MAX
INLET MIN.
11 IN. W.C.
14 IN. W.C.
(1/2 PSI)
(1/2 PSI)
TOTAL FLOW RATE DEPENDS ON THE MODEL AND NUMBER OF BURNERS. FOR FURTHER DETAILS ON
TOTAL FLOW RATE FOR THE MODEL PURCHASED, REFER TO THE " BURNER" SECTION.
DURING INSTALLATION AND CONNECTION, THE AppLIANCE GAS pIpE MUST
NOT bE TWISTED, STRETCHED OR DEFORMED IN ANY OTHER WAY CAUSING A
HAZARD TO THE USER.
THE AppLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST bE DISCONNECTED
FROM THE GAS SUppLY pIpING SYSTEM DURING ANY pRESSURE TESTING.
LEAK TEST IN EXCESS OF 1/2 pSI (3,5 kpa) OF AIR pRESSURE WILL INVALIDATE
WARRANTY.
Do not over tighten connections to the gas regulator, as this may crack the regulator and cause a gas leak. Do not
allow the regulator to turn on the pipe when tightening fittings.
The connection of the gas supply pipe to the appliance must be gastight. Make sure that the gas supply pipe does
not touch any metal parts which get hot during operation of the appliance. It must also be installed so that there is
no contact with moving parts (e.g. drawers etc.) and must not pass through spaces where it can be deformed.
LEAK TESTING OF THE AppLIANCE SHALL bE CONDUCTED ACCORDING TO THE
MANUFACTURER'S INSTRUCTIONS.
Check all connections for gas leaks using a non-corrosive leak detection fluid. Do not use a soap and water
solution. Never use a naked flame.
CONNECTING TO ELECTRICITY SUPPLY
This chapter refers only to models with the wording 12 V
CONNECT THE UNIT TO 12 V DIRECT CURRENT ONLY
DO NOT CONNECT TO HIGHER VOLTAGE
CONNECT ONLY TO pROTECTED CIRCUIT FUSED FOR NOT MORE THAN 3 Amps.
For the WIRING DIAGRAM see FIG. 4 - PAG. 32. Voltage supply must be between 9 and 13 V
GAS
INPUT
MANIFOLD
10 IN. W.C.
propane
(1/2 PSI)
on the appliance specifications label affixed to the appliance.