WARNING
THIS AppLIANCE MUST bE INSTALLED IN ACCORDANCE WITH REGULATIONS IN
FORCE AND ONLY USED IN A WELL VENTILATED SpACE. READ THE INSTRUCTIONS
bEFORE INSTALLING OR USING THIS AppLIANCE.THE AppLIANCE MUST bE
INSTALLED bY SpECIALIST TECHNICIANS.
Installation must conform with local codes or in the absence of local codes, with the American National Standard
for Recreational Vehicles, ANSI/A119.2 and the National Electrical Code, ANSI/NFPA 70. In Canada, installation
must conform with CSA Z240.4.2-M.
THE AppLIANCE IS NOT TO bE USED AS A SpACE HEATER.
This appliance is designed to cook foods only. Any other use is considered incorrect and dangerous.
Any storage cabinet placed directly above the appliance should not be used when one or more of the appliance
burners are on. The manufacturer is not responsible for any damage to persons or parts due to incorrect
installation, improper, incorrect, or irresponsible use.
For proper operation of your cooking appliance:
THE CABINET MUST BE
• properly constructed.
• squared to the countertop and cabinet face
THE OPENING IN THE CABINET MUST BE
• level from side to side and front to rear
The cabinet opening must be constructed so that no combustible material can be placed next to the cooktop sides.
The maximum depth of cabinets installed above the cooktop must be 13''.
HOLE
INFLAMMAbLE MATERIALS MUST bE KEpT AT A SAFE DISTANCE FROM THE
AppLIANCE.
MINIMUM CLEARANCES FROM THE EXTERNAL COMbUSTIbLE SURFACES (FIG.5 - PAG. 39):
SIDE CLEARANCE FROM THE EDGE OF THE
APPLIANCE TO ANY VERTICAL WALL
OVERHEAD CLEARANCE FROM THE
APPLIANCE COOKTOP TO A
RANGE-HOOD OR SHELVES
BETWEEN THE TOP EDGE OF THE
APPLIANCE AND TOP HORIZONTAL WALL
BETWEEN THE SIDE OF THE APPLIANCE
AND ADJACENT SIDE WALLS
Clearances are measured to combustible materials.
Make a hole in the furniture as indicated in FIG. 3 - PAG. 29
The cabinet must be suitably constructed and horizontally and vertically aligned.
The cabinet aperture must be perfectly squared and aligned.
If there are apertures for cabinet ventilation, avoid that any flammable material can enter these.
0 mm - 0"
762 mm - 30"
THE CLEARANCE MAY bE 495 mm - 19 1/2"
ONLY WHEN A VENT HOOD IS INSTALLED IN
ACCORDANCE WITH ANSI/NFpA 1192 ET CSA Z240
305 mm - 12"
102 mm - 4"